Equivalent PR: every dual-string MPPT string brought up to the single-string reference, then capped at each inverter's ceiling (185 kW Γ— its own setpoint) and at the site export limit. Same contract intervals and E_ideal as the real PR.
PR (contract)
β€”
PR (equivalent)
β€”
Difference
β€”
Recoverable energy
β€”
Missing DC, all bins
β€”
…of which while limited
β€”
String data coverage
β€”

Daily PR β€” actual vs equivalent

One pair of points per day (axis zoomed to the data, not from zero). The gap between them is the energy the dual-string MPPTs could have added after every ceiling is applied.

Inverters

Dual Γ· single: median ratio of dual-string to single-string string power (bins above 200 W/mΒ²), split by whether the inverter/site was at a ceiling. Allocation = strings match when unconstrained and only fall behind while limited (nothing to recover). Real loss = they fall behind even when nothing is limiting. Click a row for detail.

Inverter β€”

Each dot is one 15-min bin: x = single-string reference power, y = dual Γ· single. If the gap is power-limit allocation, the dots stay near 1.0 until a ceiling is hit and drop only in the limited classes; a real loss drops in the unconstrained class too.
Inverter AC power: actual, equivalent, and the ceiling it was held to.