Measured power ÷ model maximum power

Median measured P ÷ modelled Pmp per irradiance bin. Hover a cell for V ÷ Vmp and I ÷ Imp: low V with normal I points at a local-peak lock or mismatch; normal-to-high V with low I at a current limit.

Module temperature QC

Each 15-min reading from ModuleTemperature1/2/3 is dropped if missing, exactly 0 °C, out of range, logged in the sensor-issue log, stuck for the day, colder than ambient − 3 °C in sun, or more than 8 °C from the other valid sensors. The rest are averaged; with none left, T is estimated from ambient (NOCT model).
SensorValidMissing0 °C Out of rangeLogged issueStuckColder than ambientOutlier